1.
EBioMedicine ; 102: 105051, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458110

RESUMO

BACKGROUND: Fingertip pulse oximeters are widely available, inexpensive, and commonly used to make clinical decisions in many settings. Device performance is largely unregulated and poorly characterised, especially in people with dark skin pigmentation. METHODS: Eleven popular fingertip pulse oximeters were evaluated using the US Food and Drug Administration (FDA) Guidance (2013) and International Organization for Standardization Standards (ISO, 2017) in 34 healthy humans with diverse skin pigmentation utilising a controlled desaturation study with arterial oxygen saturation (SaO 2) plateaus between 70% and 100%. Skin pigmentation was assessed subjectively using a perceived Fitzpatrick Scale (pFP) and objectively using the individual typology angle (ITA) via spectrophotometry at nine anatomical sites. FINDINGS: Five of 11 devices had a root mean square error (ARMS) > 3%, falling outside the acceptable FDA performance range. Nine devices demonstrated worse performance in participants in the darkest skin pigmentation category compared with those in the lightest category. A commonly used subjective skin colour scale frequently miscategorised participants as being darkly pigmented when compared to objective quantification of skin pigment by ITA. INTERPRETATION: Fingertip pulse oximeters have variable performance, frequently not meeting regulatory requirements for clinical use, and occasionally contradicting claims made by manufacturers. Most devices showed a trend toward worse performance in participants with darker skin pigment. Regulatory standards do not adequately account for the impact of skin pigmentation on device performance. We recommend that the pFP and other non-standardised subjective skin colour scales should no longer be used for defining diversity of skin pigmentation. Reliable methods for characterising skin pigmentation to improve diversity and equitable performance of pulse oximeters are needed. FUNDING: This study was conducted as part of the Open Oximetry Project funded by the Gordon and Betty Moore Foundation, Patrick J McGovern Foundation, and Robert Wood Johnson Foundation. The UCSF Hypoxia Research Laboratory receives funding from multiple industry sponsors to test the sponsors' devices for the purposes of product development and regulatory performance testing. Data in this paper do not include sponsor's study devices. All data were collected from devices procured by the Hypoxia Research Laboratory for the purposes of independent research. No company provided any direct funding for this study, participated in study design or analysis, or was involved in analysing data or writing the manuscript. None of the authors own stock or equity interests in any pulse oximeter companies. Dr Ellis Monk's time utilised for data analysis, reviewing and editing was funded by grant number: DP2MH132941.


Assuntos
Oximetria , Oxigênio , Humanos , Oximetria/métodos , Hipóxia/diagnóstico , Pigmentação da Pele , Voluntários Saudáveis
2.
Med J Aust ; 200(7): 416-8, 2014 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-24794676

RESUMO

OBJECTIVE: To assess the performance of SmartVax, a prototypic active monitoring system for adverse events following immunisation (AEFI) using short message service (SMS) text messages and clinical data extracted from commercially available medical practice management software. DESIGN, SETTING AND PARTICIPANTS: Between 11 November 2011 and 10 June 2013, adult patients and parents of paediatric patients receiving routine vaccinations in general practice were sent an SMS by SmartVax enquiring if they had experienced any AEFI and requesting a reply by SMS. Attempts were made to telephone patients who did not reply by SMS. MAIN OUTCOME MEASURES: The proportion of patients sent an SMS who replied by SMS, and the proportion of respondents indicating possible AEFI. RESULTS: Of 3281 vaccinated patients, 3226 (98.3%) had a mobile telephone number on record and were sent an SMS. Of 2342 patients (72.6%; 95% CI, 70.0%-75.1%) who responded by SMS, 264 (11.3%; 95 CI, 9.9%-12.7%) reported possible AEFI. The response rate was ≥ 70% for both paediatric and adult patients. Eighty-per cent of SMS replies were received within 2 hours of transmission of the query SMS. There was no significant difference in the proportion reporting possible AEFI between patients who replied by SMS and those who did not respond by SMS but were subsequently contacted by a telephone call (P = 0.99). CONCLUSIONS: More than 70% of patients responded by SMS to an SMS query about whether they had any vaccine reactions, with the data received in near real-time. Active surveillance of AEFI using SMS has the capacity to complement existing passive reporting systems, potentially permitting more rapid identification of emerging safety signals.


Assuntos
Medicina Geral , Vacinas contra Influenza , Vacinação em Massa/estatística & dados numéricos , Envio de Mensagens de Texto/estatística & dados numéricos , Adulto , Austrália/epidemiologia , Criança , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Vacinas contra Influenza/administração & dosagem , Vacinas contra Influenza/efeitos adversos , Masculino , Vacinação em Massa/efeitos adversos , Vigilância da População , Telemedicina/métodos